Menu
Simplex PBL & EPBLs latches are currently in the process of being tested to EN 12209 allowing them to be CE Marked. Until such time as this is completed, they are not to be used on fire doors.
The use of this intumescent kit provides fire protection for the Simplex 7102, 7104 & 7108 series locks in accordance with BS EN 1634-1: 2014 for 30 minutes and has been made available for sale specifically to those with products installed without the official intumescent kit.
Fire testing was carried out using a Halspan Prima, 44mm wooden door, with the base of the lock installed 1500mm from the base of the door. Installations on doors of a lower specification or a different material than the above will require separate testing by the specifier/installer.
The fitting of intumescent material must be carried out in accordance with the fitting instructions provided with the pack.
It remains the responsibility of the specifier and installer to ensure all hardware products for use on fire doors are installed in line with the parameters to which they were tested and that they meet the required standards applicable to the entire door set. Installation must be carried out by a competent professional, holding appropriate 3rd party certification for such works.
20 Waltham Park Way
Billet Rd
London
E17 5DU
Mon-Thur 07.30-16.30 Hrs
Fri 07.30-15.00 Hrs
Tel: 0208 527 8875
5 Duckmoor Rd
Duckmoor Road Industrial Estate
Bristol
BS3 2BJ
Mon-Thur 08.00-17.00 Hrs
Fri 08.00-15.00 Hrs
Tel: 0117 953 4855
Stourbridge Rd Industrial Est
Faraday Drive
Bridgnorth
WV15 5BA
Mon-Thur 08.00-17.00 Hrs
Fri 08.00-15.00 Hrs
Tel: 01746 764846
© 2024, Door Spares Powered by Shopify